DN15-50mm, threads end
Multi-jet
Single-jet
Rotary Piston
Bypass
DN50-500, Flanged end
Accessories
 
Single-jet
 
CD74TBR-15E/S (plastic body)
 

Model CD74TBR-E/S is an inferential type, single stream vane wheel, wet dial water meter; it’s suitable for domestic use. Plastic body and adopt all antiseptic material, no leak.
 
WORKING CONDITION
*The max. admissible water pressure:1.6MPa(16bar)
*Water temp.:not more than 50℃
 
Maximum permissible error:
Between qt (included) and qs is ±2%;
Between qmin and qt (excluded) is ±5%.
NOTE: The technical data conform to ISO4064 standard, class B.

FLOW-ERROR CURVE

SPECIFICATION AND OVERALL DIMENSIONS
Description

Unit

Hydraulic data and dimensions

Nominal size

mm

15

inch

1/2

Overload flow-rate (qs)

m3/h

3

Permanent flow-rate (qp)

m3/h

1.5

Transitional flow-rate (qt)

m3/h

0.12

Minimum flow-rate (qmin)

m3/h

0.03

Max. reading

m3

99999.9999

Min. reading

m3

0.00005

Max. working pressure

MPa

1.6

ΔP at the qs

MPa

≤0.1

L

mm

110

I

mm

190

H

mm

89

B

mm

88

OVERALL DIMENSIONS                                                                      PRESSURE LOSS CURVE

 